{"id":6467,"date":"2026-04-13T12:32:02","date_gmt":"2026-04-13T05:32:02","guid":{"rendered":"https:\/\/ogrindoitb.com\/?p=6467"},"modified":"2026-04-13T12:32:04","modified_gmt":"2026-04-13T05:32:04","slug":"training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer","status":"publish","type":"post","link":"https:\/\/ogrindoitb.com\/en\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/","title":{"rendered":"Training HPLC \u2013 RID Part 2: Hands-on System Operation and Polymer Sample Analysis"},"content":{"rendered":"<p>Analysis using <em>High Performance Liquid Chromatography (HPLC) <\/em>with <em>Refractive Index Detector<\/em> (RID) is one of the important methods in the characterization of <em>chemical<\/em> EOR such as surfactants and polymers, particularly to support research needs and application of <em>Enhanced Oil Recovery <\/em>(EOR). Mastery of this method requires not only theoretical understanding but also the ability to operate the instrument and interpret data accurately. Therefore, OGRINDO ITB together with the EOR Laboratory ITB conducted <em>Training<\/em> HPLC\u2013RID <em>Part<\/em> 2, which focuses on hands-on practice and comprehensive system operation, including method setup, system operation, and troubleshooting during testing.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-1-1.png\" alt=\"\" class=\"wp-image-6472\" srcset=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-1-1.png 800w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-1-1-300x225.png 300w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-1-1-768x576.png 768w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-1-1-16x12.png 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Figure 1. HPLC\u2013RID Part 2 training with PT. Berca Niaga Medika and the EOR Laboratory ITB and OGRINDO ITB team.<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Hands-on Operation and System Setup of HPLC\u2013RID<\/strong><\/p>\n\n\n\n<p>Mastery of the instrument does not stop at understanding theory\u2014but at the ability to operate the system directly and interpret its response in <em>real-time<\/em>.<\/p>\n\n\n\n<p>In this session, the training focused on hands-on operation of the HPLC\u2013RID system comprehensively. Participants started from the initial stage of instrument operation to the analysis running process, emphasizing systematic and safe working procedures.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"6473\" src=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-10.png\" alt=\"\" class=\"wp-image-6473\" srcset=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-10.png 800w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-10-300x225.png 300w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-10-768x576.png 768w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-10-16x12.png 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"6474\" src=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-11.png\" alt=\"\" class=\"wp-image-6474\" srcset=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-11.png 800w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-11-300x225.png 300w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-11-768x576.png 768w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-11-16x12.png 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"6475\" src=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-12.png\" alt=\"\" class=\"wp-image-6475\" srcset=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-12.png 800w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-12-300x225.png 300w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-12-768x576.png 768w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-12-16x12.png 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<figcaption class=\"blocks-gallery-caption wp-element-caption\">Figure 2. Hands-on operation of the HPLC\u2013RID by participants, including sample preparation and injection process.<\/figcaption><\/figure>\n\n\n\n<p>The activities began with:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Procedures for turning on the instrument according to the operational sequence<\/li>\n\n\n\n<li>Ensuring the system is in a ready condition<\/li>\n\n\n\n<li>Recognizing indicators on the <em>software<\/em> and instrument as signs that the system has started running<\/li>\n<\/ul>\n\n\n\n<p>Next, participants performed:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Checking system readiness before analysis<\/li>\n\n\n\n<li>Setting up methods in the <em>software<\/em>, both for acquisition and <em>data processing<\/em><\/li>\n\n\n\n<li>Adjusting important parameters such as <em>baseline<\/em>, retention time, and peak integration<\/li>\n<\/ul>\n\n\n\n<p>During this process, participants also directly observed the system response to each parameter setting. This is important to understand how parameter changes can affect the resulting chromatogram.<\/p>\n\n\n\n<p>In addition, the training also emphasized conditions that commonly occur during testing, such as unstable <em>baseline<\/em> yang tidak stabil, <em>noise<\/em> , or poorly detected peaks. Participants were guided to recognize these symptoms and understand initial handling steps so that the analysis process can continue properly.<\/p>\n\n\n\n<p>This hands-on approach is key to building participants\u2019 confidence in independently operating the HPLC\u2013RID system in a laboratory environment.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-8-1.png\" alt=\"\" class=\"wp-image-6479\" srcset=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-8-1.png 800w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-8-1-300x225.png 300w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-8-1-768x576.png 768w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-8-1-16x12.png 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Figure 3. Method setup and data analysis process using HPLC <em>software<\/em> for chromatogram acquisition and interpretation.<\/figcaption><\/figure>\n<\/div>\n\n\n<figure class=\"wp-block-gallery aligncenter has-nested-images columns-default is-cropped wp-block-gallery-2 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"6476\" src=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-7.png\" alt=\"\" class=\"wp-image-6476\" srcset=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-7.png 800w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-7-300x225.png 300w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-7-768x576.png 768w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-7-16x12.png 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"6477\" src=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-6.png\" alt=\"\" class=\"wp-image-6477\" srcset=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-6.png 800w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-6-300x225.png 300w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-6-768x576.png 768w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-6-16x12.png 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<figcaption class=\"blocks-gallery-caption wp-element-caption\">Figure 4. Discussion session and direct observation of the HPLC\u2013RID system to understand operational conditions and instrument response.<\/figcaption><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong><em>Hands-on<\/em> Polymer Sample Analysis<\/strong><\/p>\n\n\n\n<p>After understanding system operation and method setup, participants then directly applied this knowledge through polymer sample testing to evaluate system performance.<\/p>\n\n\n\n<p>As the main part of the training, polymer samples were tested with several concentration variations to evaluate the RID detector response and the consistency of the analytical method used.<\/p>\n\n\n\n<p>The chromatogram results show that the polymer peak is consistently detected at a retention time of approximately 6.6 \u2013 6.9 minutes, indicating stable system conditions during the analysis.<\/p>\n\n\n\n<p>In addition, an increasing trend in peak area is observed with increasing sample concentration, indicating that the detector response is proportional to the amount of sample tested.<br>Summary of Polymer Test Results<br>60 ppm | RT: 6,898 menit | Area: 9.950<br>80 ppm | RT: 6,910 menit | Area: 12.414<br>100 ppm | RT: 6,677 menit | Area: 15.431<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-4.png\" alt=\"\" class=\"wp-image-6480\" srcset=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-4.png 800w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-4-300x225.png 300w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-4-768x576.png 768w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-4-16x12.png 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Figure 5. Chromatogram of HPLC\u2013RID analysis of polymer sample (60 ppm) showing the main peak at a retention time of approximately 6.898 minutes.<\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-5.png\" alt=\"\" class=\"wp-image-6481\" srcset=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-5.png 800w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-5-300x225.png 300w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-5-768x576.png 768w, https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-5-16x12.png 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Figure 6. Chromatogram of HPLC\u2013RID analysis of polymer sample (80 ppm) showing the main peak at a retention time of approximately 6.910 minutes.<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:31px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Brief Analysis of Test Results<\/strong><\/p>\n\n\n\n<p>The test results show that the method used has provided consistent and reliable responses. The relatively stable retention time at each concentration variation indicates that the system conditions were well maintained during the analysis.<\/p>\n\n\n\n<p>On the other hand, the increase in area values in line with concentration indicates that the RID detector is capable of providing a proportional response to the amount of polymer analyzed. This indicates that the method has good potential for use in quantitative analysis.<\/p>\n\n\n\n<p>However, at this stage, a calibration curve has not yet been applied, so the results obtained are still indicative and have not been used for absolute quantification.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Enhancement of Laboratory Analytical Competence<\/strong><\/p>\n\n\n\n<p>Through this <em>hands-on<\/em> session, participants gained practical experience in conducting HPLC\u2013RID analysis comprehensively, from system operation to interpretation of test results. Participants also learned to understand the relationship between method parameters, instrument conditions, and the quality of the resulting chromatogram.<\/p>\n\n\n\n<p>This approach not only improves technical skills but also builds analytical capabilities required in research and laboratory testing activities.<\/p>\n\n\n\n<div style=\"height:29px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Conclusion<\/strong><\/p>\n\n\n\n<p>Training HPLC\u2013RID Part 2 provides a comprehensive understanding of system operation and polymer sample analysis through hands-on practice. With a combination of instrument mastery, method understanding, and data interpretation, this training is expected to improve analysis quality and human resource readiness in supporting industrial and research needs, particularly in the EOR field.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Interested in Collaborating?<\/strong><\/p>\n\n\n\n<p>OGRINDO ITB and the EOR Laboratory ITB open opportunities for collaboration in the form of training, research, and laboratory analysis services that can be tailored to the needs of industry and academia.<\/p>\n\n\n\n<p>For more information, please contact:<br>\ud83d\udce7 OGRINDO ITB: info@ogrindoitb.com<br>\ud83d\udce7 Laboratorium EOR ITB: eor@itb.ac.id<\/p>\n\n\n\n<p>Enhance your analytical capabilities with us through research-driven training and best-practice collaboration.<\/p>","protected":false},"excerpt":{"rendered":"<p>Analisis menggunakan High Performance Liquid Chromatography (HPLC) dengan Refractive Index Detector (RID) menjadi salah satu metode penting dalam karakterisasi chemical EOR seperti surfaktan dan polimer, khususnya untuk mendukung kebutuhan riset dan aplikasi Enhanced Oil Recovery (EOR). Penguasaan metode ini tidak hanya membutuhkan pemahaman teori, tetapi juga kemampuan operasional instrumen dan interpretasi data secara akurat. Oleh [&hellip;]<\/p>","protected":false},"author":1,"featured_media":6469,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[17],"tags":[269,190,127,131,268,122,264],"class_list":["post-6467","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news-article","tag-analisis-polimer","tag-chemical-eor","tag-enhance-oil-recovery","tag-eor-laboratory-itb","tag-hplc-rid-2","tag-ogrindo-itb","tag-training-hplc"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Training HPLC \u2013 RID Part 2: Hands-on Operasional Sistem dan Analisis Sampel Polimer - OGRINDO ITB<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ogrindoitb.com\/en\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Training HPLC \u2013 RID Part 2: Hands-on Operasional Sistem dan Analisis Sampel Polimer - OGRINDO ITB\" \/>\n<meta property=\"og:description\" content=\"Analisis menggunakan High Performance Liquid Chromatography (HPLC) dengan Refractive Index Detector (RID) menjadi salah satu metode penting dalam karakterisasi chemical EOR seperti surfaktan dan polimer, khususnya untuk mendukung kebutuhan riset dan aplikasi Enhanced Oil Recovery (EOR). Penguasaan metode ini tidak hanya membutuhkan pemahaman teori, tetapi juga kemampuan operasional instrumen dan interpretasi data secara akurat. Oleh [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ogrindoitb.com\/en\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/\" \/>\n<meta property=\"og:site_name\" content=\"OGRINDO ITB\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-13T05:32:02+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-13T05:32:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-Thumbnail-Article-1024x576.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"576\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\/\/ogrindoitb.com\/#\/schema\/person\/21d3a90c7b51866eefe18eb65a048271\"},\"headline\":\"Training HPLC \u2013 RID Part 2: Hands-on Operasional Sistem dan Analisis Sampel Polimer\",\"datePublished\":\"2026-04-13T05:32:02+00:00\",\"dateModified\":\"2026-04-13T05:32:04+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/\"},\"wordCount\":797,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/ogrindoitb.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-Thumbnail-Article.png\",\"keywords\":[\"Analisis Polimer\",\"Chemical EOR\",\"Enhance Oil Recovery\",\"EOR Laboratory ITB\",\"HPLC RID\",\"Ogrindo ITB\",\"Training HPLC\"],\"articleSection\":[\"News Article\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/\",\"url\":\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/\",\"name\":\"Training HPLC \u2013 RID Part 2: Hands-on Operasional Sistem dan Analisis Sampel Polimer - OGRINDO ITB\",\"isPartOf\":{\"@id\":\"https:\/\/ogrindoitb.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-Thumbnail-Article.png\",\"datePublished\":\"2026-04-13T05:32:02+00:00\",\"dateModified\":\"2026-04-13T05:32:04+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#primaryimage\",\"url\":\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-Thumbnail-Article.png\",\"contentUrl\":\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-Thumbnail-Article.png\",\"width\":2400,\"height\":1350,\"caption\":\"Dokumentasi peserta dan tim Training HPLC\u2013RID Part 2 di Laboratorium EOR ITB yang menampilkan kegiatan analisis polimer menggunakan HPLC Refractive Index Detector untuk aplikasi EOR\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/ogrindoitb.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Training HPLC \u2013 RID Part 2: Hands-on Operasional Sistem dan Analisis Sampel Polimer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ogrindoitb.com\/#website\",\"url\":\"https:\/\/ogrindoitb.com\/\",\"name\":\"OGRINDO ITB\",\"description\":\"Oil and Gas Recovery for Indonesia\",\"publisher\":{\"@id\":\"https:\/\/ogrindoitb.com\/#organization\"},\"alternateName\":\"OGRINDO ITB\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ogrindoitb.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/ogrindoitb.com\/#organization\",\"name\":\"OGRINDO ITB\",\"alternateName\":\"Oil and Gas Recovery for Indonesia\",\"url\":\"https:\/\/ogrindoitb.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ogrindoitb.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2024\/03\/OGRINDO-FINAL-favicon2.png\",\"contentUrl\":\"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2024\/03\/OGRINDO-FINAL-favicon2.png\",\"width\":1038,\"height\":1038,\"caption\":\"OGRINDO ITB\"},\"image\":{\"@id\":\"https:\/\/ogrindoitb.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/ogrindoitb.com\/#\/schema\/person\/21d3a90c7b51866eefe18eb65a048271\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ogrindoitb.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/0b0f56a2e58225c6e6703e9d5218af6f1a8ee490e96715db82c262c1f6396b45?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/0b0f56a2e58225c6e6703e9d5218af6f1a8ee490e96715db82c262c1f6396b45?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\/\/unitest.co.id\"],\"url\":\"https:\/\/ogrindoitb.com\/en\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Training HPLC \u2013 RID Part 2: Hands-on Operasional Sistem dan Analisis Sampel Polimer - OGRINDO ITB","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ogrindoitb.com\/en\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/","og_locale":"en_US","og_type":"article","og_title":"Training HPLC \u2013 RID Part 2: Hands-on Operasional Sistem dan Analisis Sampel Polimer - OGRINDO ITB","og_description":"Analisis menggunakan High Performance Liquid Chromatography (HPLC) dengan Refractive Index Detector (RID) menjadi salah satu metode penting dalam karakterisasi chemical EOR seperti surfaktan dan polimer, khususnya untuk mendukung kebutuhan riset dan aplikasi Enhanced Oil Recovery (EOR). Penguasaan metode ini tidak hanya membutuhkan pemahaman teori, tetapi juga kemampuan operasional instrumen dan interpretasi data secara akurat. Oleh [&hellip;]","og_url":"https:\/\/ogrindoitb.com\/en\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/","og_site_name":"OGRINDO ITB","article_published_time":"2026-04-13T05:32:02+00:00","article_modified_time":"2026-04-13T05:32:04+00:00","og_image":[{"width":1024,"height":576,"url":"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-Thumbnail-Article-1024x576.png","type":"image\/png"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#article","isPartOf":{"@id":"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/"},"author":{"name":"admin","@id":"https:\/\/ogrindoitb.com\/#\/schema\/person\/21d3a90c7b51866eefe18eb65a048271"},"headline":"Training HPLC \u2013 RID Part 2: Hands-on Operasional Sistem dan Analisis Sampel Polimer","datePublished":"2026-04-13T05:32:02+00:00","dateModified":"2026-04-13T05:32:04+00:00","mainEntityOfPage":{"@id":"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/"},"wordCount":797,"commentCount":0,"publisher":{"@id":"https:\/\/ogrindoitb.com\/#organization"},"image":{"@id":"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#primaryimage"},"thumbnailUrl":"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-Thumbnail-Article.png","keywords":["Analisis Polimer","Chemical EOR","Enhance Oil Recovery","EOR Laboratory ITB","HPLC RID","Ogrindo ITB","Training HPLC"],"articleSection":["News Article"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/","url":"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/","name":"Training HPLC \u2013 RID Part 2: Hands-on Operasional Sistem dan Analisis Sampel Polimer - OGRINDO ITB","isPartOf":{"@id":"https:\/\/ogrindoitb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#primaryimage"},"image":{"@id":"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#primaryimage"},"thumbnailUrl":"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-Thumbnail-Article.png","datePublished":"2026-04-13T05:32:02+00:00","dateModified":"2026-04-13T05:32:04+00:00","breadcrumb":{"@id":"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#primaryimage","url":"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-Thumbnail-Article.png","contentUrl":"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2026\/04\/HPLC-RID-Training-Series-Part-2-Thumbnail-Article.png","width":2400,"height":1350,"caption":"Dokumentasi peserta dan tim Training HPLC\u2013RID Part 2 di Laboratorium EOR ITB yang menampilkan kegiatan analisis polimer menggunakan HPLC Refractive Index Detector untuk aplikasi EOR"},{"@type":"BreadcrumbList","@id":"https:\/\/ogrindoitb.com\/training-hplc-rid-part-2-hands-on-operasional-sistem-dan-analisis-sampel-polimer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ogrindoitb.com\/"},{"@type":"ListItem","position":2,"name":"Training HPLC \u2013 RID Part 2: Hands-on Operasional Sistem dan Analisis Sampel Polimer"}]},{"@type":"WebSite","@id":"https:\/\/ogrindoitb.com\/#website","url":"https:\/\/ogrindoitb.com\/","name":"OGRINDO ITB","description":"Oil and Gas Recovery for Indonesia","publisher":{"@id":"https:\/\/ogrindoitb.com\/#organization"},"alternateName":"OGRINDO ITB","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ogrindoitb.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ogrindoitb.com\/#organization","name":"OGRINDO ITB","alternateName":"Oil and Gas Recovery for Indonesia","url":"https:\/\/ogrindoitb.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ogrindoitb.com\/#\/schema\/logo\/image\/","url":"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2024\/03\/OGRINDO-FINAL-favicon2.png","contentUrl":"https:\/\/ogrindoitb.com\/wp-content\/uploads\/2024\/03\/OGRINDO-FINAL-favicon2.png","width":1038,"height":1038,"caption":"OGRINDO ITB"},"image":{"@id":"https:\/\/ogrindoitb.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/ogrindoitb.com\/#\/schema\/person\/21d3a90c7b51866eefe18eb65a048271","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ogrindoitb.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/0b0f56a2e58225c6e6703e9d5218af6f1a8ee490e96715db82c262c1f6396b45?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0b0f56a2e58225c6e6703e9d5218af6f1a8ee490e96715db82c262c1f6396b45?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/unitest.co.id"],"url":"https:\/\/ogrindoitb.com\/en\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/ogrindoitb.com\/en\/wp-json\/wp\/v2\/posts\/6467","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ogrindoitb.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ogrindoitb.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ogrindoitb.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ogrindoitb.com\/en\/wp-json\/wp\/v2\/comments?post=6467"}],"version-history":[{"count":5,"href":"https:\/\/ogrindoitb.com\/en\/wp-json\/wp\/v2\/posts\/6467\/revisions"}],"predecessor-version":[{"id":6484,"href":"https:\/\/ogrindoitb.com\/en\/wp-json\/wp\/v2\/posts\/6467\/revisions\/6484"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ogrindoitb.com\/en\/wp-json\/wp\/v2\/media\/6469"}],"wp:attachment":[{"href":"https:\/\/ogrindoitb.com\/en\/wp-json\/wp\/v2\/media?parent=6467"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ogrindoitb.com\/en\/wp-json\/wp\/v2\/categories?post=6467"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ogrindoitb.com\/en\/wp-json\/wp\/v2\/tags?post=6467"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}